Any other exterior door has a threshold height limited to 7 inches.
Irc required garage door.
The international residential code irc requires a self closing device on this door but we have no such requirement here in minnesota.
A remodeler doing a flip house changes out all the doors in the home to update the interior and replaces the old door to the garage with a hollow core interior door.
This door assembly is not specifically required to be fire rated.
The international residential code table is similar.
Openings in garage walls shall comply with section r302 5.
We used to but we ve since amended that requirement out of our code.
2018 irc section r311 3 1 restricts threshold height a required exit door in residences to 1 inches from the top of the the threshold to the floor or landing on each side of the door.
By the way cutting a hole in the door to install a pet door flap voids the 20 minute rating.
International residential code page 1 of 2 chapter 3 building planning section r302 6 2015 edition irc interpretation 04 16 issued 5 19 2016 re 15 04 16 r302 6 dwelling garage fire separation.
Means of egress doors in the irc.
1 2 drywall is all that is required on the wall between the house and the garage and on walls that support rooms above the garage.
These doors shall also be equipped with a self closing device.
Door to house this is the only place where any fire rating is specified.
Typically doors to breezeways.
26 gage sheet metal or another approved material they also can t open to the garage.
These doors shall not open into a sleeping room.
Doors separating the garage and living spaces shall be 1 3 8 solid wood solid or honeycomb core steel doors not less than 1 3 8 thick or 20 minute rated doors.
Dasma garage door wind load guide based on the 2000 2003 2006 international residential codes irc similar to other doors and windows the design and installation of garage doors and frames shall comply with the design wind load for the structure.
Wind resistant garage door and frame installation code reference.
One example of a problem area is the entry door between the garage and the residence.
May 6 2018 at 4 47 pm.
R302 11 fireblocking item 4.
We recommend that the door between garage and residence should be equipped with a self closing device although no longer required by the irc and fbc.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The garage shall be separated as required by table r302 6.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
One could make the argument that given the wording in irc 302 5 1 a fire rated door or its equivalent is required.
If the door is not solid wood or steel honeycomb and at least 1 3 8 thick then it must have a 20 minute fire rating.