The iic rating is the determined by using a standard tapping machine with five steel faced hammers to strike a test floor material generating sounds between 125 hz 4000 hz.
Iic rating for carpet.
The impact creates vibrations that travel through the flooring and produce sounds on the other side.
An iic and stc rating will generally be 5 points higher than.
The top layer of flooring is only the tip of the iceberg for flooring sound transmission.
Iic values can range from as low as 25 for lightweight residential construction with no floor covering to over 65 for commercial construction with carpet.
I hope this information was helpful for you.
More typical values fall between 35 and 55.
The higher the rating the less sound gets through.
The iic rating of a condo unit floor above another condo unit should be 75 or more to match what is provided by carpet and reasonably thick carpet padding.
The subfloor ceiling assembly and presence of an underlayment during testing impact the rating from one manufacturer to.
So no 1 4 inch cork is not adequate on concrete.
But when you compare products look beyond the number.
The highest rating is iic rating 65 which includes cork flooring and carpet.
The main test done by flooring industry is the impact insulation class iic ad sound transmission class stc.
A f iic and f stc rating.
Carpet with an nrc rating of 40 50 is the most efficient absorptive material.
For multi family structures some codes require an iic of 50 or more when tested in the laboratory or 45 or more when tested in the field.
The impact insulation class iic rating is a measurement of sound transmission from the floor to a room beneath it.
The transmission of these sounds through floor ceiling assemblies such as those found in multi level homes and apartments will be inhibited by underlayments with higher iic and stc ratings.
The iic rating measures impact sounds such as footfalls dropped objects etc.
The f iic and f stc is conducted in the field where sound is not as controllable hence the 5 point difference.
When evaluating flooring underlayment sound deadening and acoustical ratings are one of the things homeowners or hoa considers.
A midrange level is iic rating 60 which includes some vinyl flooring as well as wood and laminate floors.
It all begins with how sound is generated and the medium it transfers through.
The iic and stc is conducted at a controlled laboratory.
An iic rating 50 means that the flooring material has minimal sound absorption capabilities.